12.6mm Isolated Pressure Sensing Cell

12.6mm Isolated Pressure Sensing Cell

Details
•All-Metal Isolated Diaphragm - Harsh Media Compatibility
•Wide Pressure Ranges: 0~100kPa…60MPa
•Absolute/Gauge Pressure Measurement
•Ø12.6mm Compact & Standardized Design
•Flexible Power Supply - Voltage & Current options
•Customization Available
Category
Pressure Transducer
Share to
Send Inquiry
Description
Technical Parameters

Product Introduction

  • Our Isolated Pressure Sensing Cell is a high-performance piezoresistive pressure sensor featuring an all-metal isolation structure. Utilizing a precision silicon sensing die housed in a stainless steel enclosure (Ø12.6mm), it transmits media pressure through an isolated diaphragm to accurately convert pressure into stable electrical signals and effectively protecting the internal sensing die from corrosive and viscous media.

  • Each sensing cell undergoes rigorous testing and calibration to ensure exceptional reliability across a wide pressure range (0-100kPa to 60MPa), with an operating temperature of -40°C to 125°C and rapid 1.0ms response time.

  • This 12.6mm isolated pressure sensing cell is designed to meet the demanding requirements of test and measurement, hydraulics, and process control, achieving extremely low drift and stable performance.

Features

Harsh Environment Ready

The all-metal isolated diaphragm (316L Stainless Steel) ensures compatibility with corrosive media, providing superior durability in chemical, hydraulic, and process applications.

01

High Accuracy and Long-Term Stability

Based on high-stability MEMS technology, this sensor delivers excellent performance across a wide operating temperature range of -40°C to 125°C and a fast response time of 1.0ms.

02

Compact Design with Flexible Power Supply

The compact Ø12.6mm form factor and multiple power supply options ensure seamless compatibility with your control systems.

03

Dedicated tailored Customization

Get a tailored solution, not just an off-the-shelf product. We partner with you to customize pressure ranges, electrical interfaces to meet your specific application requirements.

04

Specifications

 

Measured Medium Liquid or Gas Compatible with SS316L

Operating Temperature Range

-40℃~125℃

Pressure Range

0~100kPa…60MPa

Over Pressure

1.5FS

Burst Pressure

2FS

Nonlinearity

±0.25%FS

Repeatability

±0.1%FS

Hysteresis

±0.1%FS

Power Supply

2V~12V DC/0.5mA~2mA

Electrical Connection

Kovar Pins

Wetted Parts

Stainless Steel

Housing Diameter

∅12.6mm

 

Application

 

 

Industrial Automation & Process Control

This 12.6mm isolated pressure sensing cell is ideal for monitoring and controlling pressure in hydraulic systems, pneumatic circuits, pumps, compressors, and industrial machinery.

 

 

Chemical & Petrochemical Processing

The all-metal isolated diaphragm provides excellent compatibility with corrosive media, making it suitable for chemical injection, reactor vessel monitoring, and fluid handling systems.

 

 

Medical & Laboratory Equipment

Used in gas and liquid pressure monitoring of ventilators, anesthesia machines, blood analyzers, etc. due to its high accuracy and reliability.

 

 

Test & Measurement Systems

Provides high-accuracy data acquisition for pressure calibration benches, sensor test stands, wind tunnels, and research and development applications.

 

 

OEM & Customized Solutions

A preferred component for Original Equipment Manufacturers (OEM) in need of a compact, reliable, and customizable pressure sensing solution for integration into their products.

Kind Tips

 

  • Media Compatibility Check

Always ensure the measured media is chemically compatible with the sensor's wetted materials (typically 316L Stainless Steel isolation diaphragm). Incompatible media can cause corrosion and sensor failure.

  • Do Not Exceed Pressure Limits

The applied pressure must never exceed the sensor's rated pressure and especially its burst pressure limit. Avoid pressure spikes or water hammer effects in the system, which can cause irreversible damage.

  • Operating Environment Considerations

Ensure the sensor operates within its specified temperature range (e.g., -40°C to 125°C). Avoid rapid thermal shock, which can affect measurement accuracy and potentially damage the sensor.

  • Proper Handling, Transportation & Storage

Handle with care to prevent mechanical shock or impact that could affect calibration.

For long-term storage, keep the sensor in its original packaging in a dry, cool environment free of corrosive gases. Regular checks are recommended.

 

FAQ

Q: What is an isolated pressure sensor, and why is it better than a non-isolated type?

A: An Isolated Pressure Sensor, like our Isolated Pressure Sensing Cell, features a physical barrier (typically a stainless steel diaphragm) that separates the process media from the internal sensing element. This isolation is superior for measuring corrosive or viscous media, as it protects the sensor from damage, ensures long-term stability, and prevents media contamination, which is a common point of failure in non-isolated sensors.

Q: What is the operating temperature range of your isolated pressure sensing cell?

A: The operating temperature range of a pressure sensor refers to the temperature range within which the sensor can function normally and produce accurate, reliable measurements. Operating temperature is a critical parameter because it affects the sensor's internal components, such as the sensing element and electronic components. If temperatures exceed the specified operating range, sensor performance may be compromised, measurements may become inaccurate or unreliable, and in severe cases, the sensor may fail.

Q: Is this pressure sensor compatible with my specific media? 

A: Yes, our sensing cell is designed for harsh media compatibility. The all-metal isolated diaphragm is made from 316L stainless steel, which is highly resistant to a wide range of corrosive media, including water, oils, most chemicals, and viscous fluids.

 

Hot Tags: 12.6mm isolated pressure sensing cell, China 12.6mm isolated pressure sensing cell manufacturers, suppliers, factory, 12 6mm Isolated Pressure Sensing Cell, 19mm Isolated Pressure Sensing Cell, I2C Digital Output Board Mount Pressure Sensor, Millivolt Output Board Mount Pressure Sensor, pressure transducer, TO 8 Millivolt Output Pressure Sensor

Send Inquiry
Contact usfor expert support

You can contact us via phone, email or online form below, and our team will respond promptly.

Contact now!