Coriolis Mass Flow Meter

Coriolis Mass Flow Meter

Details
• ±0.1% High Accuracy · Direct Mass Flow · Multi-Variable Measurement · No Straight Pipe Required
• The Coriolis mass flow meter is a precision instrument that directly measures mass flow rate based on the Coriolis force principle. Suitable for liquids, gases, and slurries, it delivers ±0.1% accuracy, simultaneous density and temperature measurement, and stable performance across a wide range of process conditions. Available in sizes from DN06 to DN80, with temperature capability from -200°C to +350°C.
Category
Flow Meter
Share to
Send Inquiry
Description
Technical Parameters
Key Features

 

Direct Mass Flow Measurement

Measures mass flow directly, independent of fluid density, temperature, or pressure changes. No additional calculations or corrections required.

High Accuracy ±0.1%

Industry-leading accuracy with 20:1 turndown ratio. Repeatability of ±0.05% ensures reliable and consistent measurement.

Multi-Variable Measurement

Simultaneously measures mass flow, volume flow, density, and temperature in a single device. Reduces equipment costs and installation complexity.

Wide Temperature & Pressure Range

Operates from -200°C to +350°C with process pressure up to 10MPa. Suitable for cryogenic, high-temperature, and high-pressure applications.

No Straight Pipe Requirement

No upstream or downstream straight pipe lengths required. Flexible installation in tight spaces and existing piping systems.

Low Maintenance

No moving parts, no wear components. Minimal maintenance required, reducing downtime and operating costs.

Product Overview

  • The Coriolis mass flow meter (also known as a Coriolis flowmeter or Coriolis mass flowmeter) is a device that measures the mass flow rate of a fluid traveling through a vibrating tube. When fluid flows through the oscillating tube, it generates a Coriolis force proportional to the mass flow rate. The meter detects the phase shift between the inlet and outlet sides of the tube, which is directly proportional to the mass flow.

  • This Coriolis meter consists of a sensor (flow tubes, drivers, and pick-off coils) and a transmitter (electronics for signal processing and output). Available in both integral (compact) and remote (split) mounting configurations, the meter offers flexibility for various installation environments. With sizes ranging from DN06 to DN80, it accommodates flow rates from low-flow to high-capacity applications.

  • Unlike volumetric flow meters, the Coriolis mass flow meter provides direct mass flow measurement that is immune to changes in fluid properties-making it the preferred choice for custody transfer, batching, and critical process control.

Specifications

Measurement Principle Coriolis force (direct mass flow measurement)
Measured Media Liquids, gases, slurries, viscous fluids
Nominal Sizes DN06, DN15, DN25, DN50, DN80
Mass Flow Accuracy (Liquid) ±0.1% of rate
Mass Flow Repeatability ±0.05% of rate
Volume Flow Accuracy ±0.15% of rate
Volume Flow Repeatability ±0.075% of rate
Density Accuracy ±0.002 g/cm³ (±2.0 kg/m³)
Density Repeatability ±0.0005 g/cm³ (±0.5 kg/m³)
Density Range 0.2 g/cm³ ~ 3.0 g/cm³ (200 kg/m³ ~ 3000 kg/m³)
Temperature Accuracy ±0.5°C
Temperature Repeatability ±0.2°C
Process Temperature Range -200°C ~ +350°C
Ambient Temperature Range -40°C ~ +55°C (operation); -40°C ~ +70°C (storage)
Maximum Process Pressure Up to 10MPa
Wetted Materials 316L stainless steel (standard); C-22, 304, Tantalum, Zirconium (optional)
Enclosure Material 304 stainless steel (sensor); Cast aluminum with epoxy coating (transmitter)
Protection Rating IP65
Electrical Output 4-20mA (active/passive), frequency (0-10kHz), RS485, HART
Power Supply 24VDC (1A max) or 220VAC (0.1A max)
Power Consumption Max 30W
Mounting Options Integral (compact) or remote (split) installation
Ex Approvals ATEX, IECEx, NEPSI (available upon request)

Application

The Coriolis mass flow meter is the preferred solution for applications requiring high-accuracy direct mass flow measurement across a wide range of fluids and process conditions. Its ability to measure mass flow, density, and temperature simultaneously-without being affected by changes in fluid properties-makes it ideal for custody transfer, process control, batching, and quality assurance in industries from oil and gas to pharmaceuticals and food production.

 

Chemical & petrochemical processing

Power generation & energy management

Slurry & suspension flow measurement

Automotive fuel & fluid testing

Oil & gas custody transfer

Pharmaceutical batching & dosing

Food & beverage production

 

Pulp & paper manufacturing

High-temperature process monitoring

Cryogenic fluid measurement (LNG, liquid nitrogen)

External dimensions

Integrated installation

product-521-333

Separate installation

product-691-308

FAQ

Q: What is a Coriolis mass flow meter and how does it work?

A: A Coriolis mass flow meter measures mass flow rate using the Coriolis force principle. Fluid flowing through a vibrating tube generates a Coriolis force that causes a phase shift between the inlet and outlet sides of the tube-this phase shift is directly proportional to the mass flow rate. The meter directly measures mass flow without requiring temperature or pressure compensation.

Q: What fluids can a Coriolis mass flow meter measure?

A: Coriolis mass flow meters are suitable for a wide range of fluids including liquids, gases, slurries, viscous fluids, and multi-phase mixtures. Common applications include chemicals, hydrocarbons, food products, pharmaceuticals, cryogenic fluids, and high-temperature process streams.

Q: Does a Coriolis flow meter require straight pipe lengths upstream and downstream?

A: No. Unlike many other flow meter technologies, Coriolis mass flow meters do not require straight pipe runs upstream or downstream. This makes them ideal for installation in tight spaces, retrofits, and applications with limited piping layout flexibility.

Q: What is the difference between mass flow and volume flow measurement?

A: Mass flow measures the actual mass of fluid passing through the meter (e.g., kg/h), which is independent of temperature and pressure. Volume flow measures the volumetric quantity (e.g., L/h), which varies with fluid density changes. Coriolis meters provide direct mass flow measurement, which is more accurate and reliable for process control and custody transfer.

Q: What communication protocols are supported?

A: The Coriolis mass flow meter supports multiple communication options including 4-20mA analog output, frequency/pulse output, RS485 Modbus, and HART protocol. Custom communication protocols can be configured upon request.

Q: Can the meter be used in hazardous areas?

A: Yes. The Coriolis mass flow meter is available with ATEX, IECEx, and NEPSI ex approvals for installation in hazardous areas. Please consult our sales team for specific certification requirements.

Q: What is the turndown ratio and why does it matter?

A: Turndown ratio is the range between the maximum and minimum flow rates that the meter can measure while maintaining specified accuracy. Our Coriolis mass flow meter offers a 20:1 turndown ratio, meaning it maintains ±0.1% accuracy from 5% to 100% of full scale-providing excellent performance across a wide operating range.

Q: How do I select the right size Coriolis mass flow meter for my application?

A: Size selection depends on your expected flow rate, fluid properties, process temperature and pressure, and available piping connections. Our engineering team can assist with sizing calculations and recommendations based on your specific application requirements-contact us for a free consultation.

 

Hot Tags: coriolis mass flow meter, China coriolis mass flow meter manufacturers, suppliers, factory, full bore flow meter, Intrinsically Safe Flowmeter, low flow flow meter, pony flow meter, visual flow meter, volume flow meter

Send Inquiry
Contact usfor expert support

You can contact us via phone, email or online form below, and our team will respond promptly.

Contact now!