Product Introduction
-
The Rail Mount Temperature Transmitter is a highly integrated signal conditioning device designed for industrial automation applications. It efficiently converts signals from RTD or thermocouple sensors into standardized current or voltage outputs, ensuring accurate and reliable temperature measurement.
-
Engineered for easy installation, the transmitter mounts directly on standard DIN rails, saving space in the control cabinet and simplify system wiring. Its compact design incorporates high-reliability components and SMT assembly technology, delivering stable performance across a wide operating temperature range with excellent EMI resistance.
-
The rail mount temperature transmitter features versatile input compatibility supporting various temperature sensors, along with clear LED status indicators for instant operational feedback. Designed for convenience, it enables tool-free installation and removal, reducing maintenance downtime and providing a practical plug-and-play solution for process control and equipment monitoring systems.
-
Ideal for HVAC, energy management, and smart manufacturing applications, this rail mount temperature transmitter offers a robust and efficient solution for temperature signal acquisition and conversion.
Features
Easy DIN Rail Installation
Features standard DIN rail mounting for quick and organized cabinet integration, simplifying wiring and saving installation time.
01
Powerful Signal Compatibility
It supports a wide range of temperature sensor inputs, including thermocouples and RTDs, delivering stable, noise-resistant standardized output signals.
02
Rugged & Compact Design
Space-saving housing with high resistance to vibration and EMI, ensuring reliable performance in harsh industrial environments.
03
Flexible Configuration
Offers multiple output and power options with LED status indicators for easy monitoring and plug-and-play maintenance.
04
Specifications
|
Type |
Platinum resistors: pt100, pt1000, pt500, pt200 Thermocouples: K/J/N/E/S/T/R/B Thermistors: 5K, 10K, 100K, 50K, 2.2K DS18B20 |
|
Accuracy |
Platinum Resistors: Class A, B, 1/3B Thermocouples: Class I, II Thermistors: 1%, 2%, 3% DS18B20: none |
|
Temperature Range |
Platinum resistance: -200℃ to 850℃ Thermocouple: -280℃ to 1820℃ Thermistor: -50℃ to 300℃ DS18B20: -55℃ to 125℃ |
|
Connection |
Platinum resistors: T=two-wire; S=two-wire; F=four-wire Thermocouples: none Thermistors: none DS18B20: none |
|
Sheath Diameter (mm) |
2, 3, 4, 5, 6, 8, 10.... .20 or specified |
|
Sheath Length (mm) |
10~2000 or specified |
|
Process Connection |
Flange |
Application
Industrial Automation Control
The rail mount temperature transmitter widely used in PLC cabinets, distribution boxes, and control panels for centralized signal conversion and temperature monitoring in automated production lines and robotic systems.
Building Management Systems
Ideal for HVAC control, energy management systems, and indoor climate monitoring in commercial buildings, data centers, and smart facilities.
Process Instrumentation Integration
Essential in oil and gas, chemical, and pharmaceutical industries for signal conditioning and transmission from temperature sensors in reactors, pipelines, and storage tanks.
Equipment Manufacturing & OEM Integration
Built into machinery control cabinets, industrial ovens, packaging equipment, and other automated systems for real-time temperature protection and monitoring.
Power System Monitoring
Used in substations, switchgear, transformer monitoring, and power distribution units for overheating detection and preventive maintenance.
Kind Tips
- Secure Mounting
During installation, ensure the correct rail model is used. After installation, check that the clips are securely locked.
- Wiring Safety
Always disconnect power before wiring. Connect the components strictly according to the wiring diagram, and pay attention to power polarity.
- Thermal Management
Maintain adequate ventilation space around the transmitter and avoid high ambient temperatures.
- Interference Prevention
Route signal cables separately from power lines. Use shielded cables when necessary to prevent interference.
- Routine Maintenance
Regularly check the fixing clips for looseness, clean any accumulated dust, and maintain adequate ventilation.
- Environmental Limits
Avoid installation in areas with excessive humidity, strong vibration, or corrosive atmospheres.
FAQ
Q: How do I install the transmitter on a DIN rail?
A: Simply align the transmitter with the standard DIN rail (35mm) and push until the locking clip snaps into place. Ensure the clip is fully engaged for secure mounting.
Q: Is the transmitter resistant to electrical noise?
A: Yes, this rail mount temperature transmitter features high EMC immunity and internal isolation. For best performance, use shielded cables and avoid routing signal lines parallel to power cables.
Q: How can I monitor its status?
A: Many models include LED indicators for power and signal status, providing visual confirmation of normal operation.
Q: What protections can I get?
A: The product has a one-year warranty. During this period, we will repair or replace any product quality issues and provide ongoing strong technical support.
Hot Tags: rail mount temperature transmitter, China rail mount temperature transmitter manufacturers, suppliers, factory, Rail Mount Temperature Transmitter, temperature transmitter pt100, skin type temperature transmitter, isolated temperature transmitter, 0 10v temperature transmitter, integrated temperature transmitter